Manufactur standard Hose Nozzle - RUBBER Fire Hose – Minshan
Fire Hose Description: The lining of fire hose is PVC, Rubber or Copy Rubber. And the double jacket of fire delivery hose is woven by high intensity of polyester filament or polyester short-fiber( twill/plain ). 1.Construction of Canvas Lay flat Hose -Tube: NR, NBR, EPDM, PVC Liner -Reinforcement: High tensile fiber braid reinforcement -Cover: Canvas surface 2.Color available: Normally use black, red, yellow. We also produce by request of customers. 3. Working area: fire protection... -
Hot sale Fire Hose Equipment - STORZ Fire Hose Coupling – Minshan
Features: –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Wor... -
Manufacturer for Sprayers - Pendent Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTX DN15 R1/2 80±4 5.6 Pendent fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray head is general... -
Rapid Delivery for Fire Hose Testing - RUBBER Fire Hose – Minshan
Fire Hose Description: The lining of fire hose is PVC, Rubber or Copy Rubber. And the double jacket of fire delivery hose is woven by high intensity of polyester filament or polyester short-fiber( twill/plain ). 1.Construction of Canvas Lay flat Hose -Tube: NR, NBR, EPDM, PVC Liner -Reinforcement: High tensile fiber braid reinforcement -Cover: Canvas surface 2.Color available: Normally use black, red, yellow. We also produce by request of customers. 3. Working area: fire protection... -
OEM Supply Foam Spraying Monitor - Spray Fire Nozzle – Minshan
Working principle: The fire water spray nozzle is an important component in the automatic water spray fire extinguishing system. It forms an automatic spray fire extinguishing system with the water supply pipe network, control valve, fire detection and alarm device, etc. Because the water droplets sprayed do not exceed 1mm, they become mist droplets spread , Improves the efficiency of fire extinguishing, and the mist water droplets will not cause the splash of liquid fire and the conduction... -
Factory Price For Fog Mist Nozzle - PU Fire Hose – Minshan
Technical Specifications Item: Lined Fire Hose Fire Hose Type: Single Jacket Hose Tube Material: PVC Nitrile Hose Cover Material: Rubber Quality Standard: EN14540,BS6391 Hose & Coupling Sizes Size Large Diameter High water flow Hydrant Ready Easy Handing Pump Ready 1’’ √ √ √ √ √ 1.5’’ √ √ √ √ √ 2’’ √ √ √ √ √ 2.5’’ √ √ √ √ √ 3’’ √ √ √ √ √ 4’’ √ √ √ √ √ Features: Working Pres... -
Factory selling Fire Hose Fittings - FIRE NOZZLE – Minshan
Working principle: It is a water jetting tool for fire extinguishing. When it is connected with the hose, it will spray dense and full water flow, which has the advantages of long range and large water volume. Specification: MODEL Style Size MS-BN fire nozzle 1 1/2’’ 2’’ 2 1/2’’ How to use: 1.Pull open the fire hydrant door, take out the hose and water gun. 2.Check whether the hose and connector are in good condition. If it is damaged, it is forbidden to use... -
PriceList for Pendent Sprinkler - Water Curtain Fire Sprinkler – Minshan
Working principle: The water curtain sprinkler is a spray device fixed in the water curtain system pipe, which is used to continuously spray water to form a water curtain, protect the surface threatened by fire and form a fire separation. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style MS-WCS DN15 R1/2 80±4 5.6 fire sprinkler DN20 R3/4 115±6 8.0 DN25 R1 242 16.8 How to use: The water curtain sprinklers should be evenly arranged according to the requ... -
Reasonable price Concealed Fire Sprinkler - Sidewall Fire Sprinkler – Minshan
Working principle: The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification: MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTBS DN15 R1/2 80±4 5.6 Horizontal sidewall fire sprinkler DN20 R3/4 115±6 8.0 How to use: 1. The installation distance of the spray he... -
Excellent quality Machino Fire Hose Coupling - GOST Fire Hose Coupling – Minshan
Features: –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Worki... -
Hot sale Fire-Fighting Nozzle - Spray Fire Nozzle – Minshan
Working principle: The fire water spray nozzle is an important component in the automatic water spray fire extinguishing system. It forms an automatic spray fire extinguishing system with the water supply pipe network, control valve, fire detection and alarm device, etc. Because the water droplets sprayed do not exceed 1mm, they become mist droplets spread , Improves the efficiency of fire extinguishing, and the mist water droplets will not cause the splash of liquid fire and the conduction... -
Factory wholesale Dry Powder Extinguisher - Dry Powder Fire Extinguisher – Minshan
Working principle Dry Chemical fire extinguishers extinguish the fire primarily by interrupting the chemical reaction of the fire triangle. Today’s most widely used type of fire extinguisher is the multipurpose dry chemical that is effective on Class A,B,and C fires. This agent also works by creating a barrier between the oxygen element and the fuel element on Class A fires. Ordinary dry chemical is for Class B & C fires only. It is important to use the correct extinguisher for the type o...