Featured

  • Hot Selling for Conventional Fire Sprinkler Head - Spray Fire Nozzle – Minshan

    Hot Selling for Conventional Fire Sprinkler Head - Spray Fire Nozzle – Minshan

    Working principle:   The fire water spray nozzle is an important component in the automatic water spray fire extinguishing system. It forms an automatic spray fire extinguishing system with the water supply pipe network, control valve, fire detection and alarm device, etc. Because the water droplets sprayed do not exceed 1mm, they become mist droplets spread , Improves the efficiency of fire extinguishing, and the mist water droplets will not cause the splash of liquid fire and the conduction...
  • Factory Price For Sprinkler Irrigation System - Spray Fire Nozzle – Minshan

    Factory Price For Sprinkler Irrigation System - Spray Fire Nozzle – Minshan

    Working principle:   The fire water spray nozzle is an important component in the automatic water spray fire extinguishing system. It forms an automatic spray fire extinguishing system with the water supply pipe network, control valve, fire detection and alarm device, etc. Because the water droplets sprayed do not exceed 1mm, they become mist droplets spread , Improves the efficiency of fire extinguishing, and the mist water droplets will not cause the splash of liquid fire and the conduction...
  • Discount Price Floor Flange 3/4 - Fire Flange Landing Valve – Minshan

    Discount Price Floor Flange 3/4 - Fire Flange Landing Valve – Minshan

    Working principle:   The Flange Landing Valve is supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of.   Specification:   MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN16 ...
  • Europe style for Brass Nozzle - Fire HydrantLanding Valve – Minshan

    Europe style for Brass Nozzle - Fire HydrantLanding Valve – Minshan

    Working principle:   The Fire HydrantLanding Valve supplied by the indoor pipe network to the fire site with a valve interface. It is a fixed fire-fighting facility for factories, warehouses, high-rise buildings, public buildings and ships. It is usually installed in the fire hydrant box and is connected to the fire hose and water nozzle Supporting the use of.   Specification:   MODEL Nominal Diameter Thread Nominal Pressure Style MS-FLV DN40 1 1/2 PN16 Flange Landing Valve DN50 2 PN1...
  • 100% Original Fire Sprinkler Spray Nozzle - Upright Fire Sprinkler – Minshan

    100% Original Fire Sprinkler Spray Nozzle - Upright Fire Sprinkler – Minshan

    Working principle:   The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water. Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTZ DN15 R1/2 80±4 5.6 Upright fire sprinkler DN20 R3/4 115±6 8.0 How to use:   1. The installation distance of the spray head is generally...
  • High Quality Fire Hose Manufacturers - PU Fire Hose – Minshan

    High Quality Fire Hose Manufacturers - PU Fire Hose – Minshan

    Technical Specifications   Item: Lined Fire Hose Fire Hose Type: Single Jacket Hose Tube Material: PVC  Nitrile Hose Cover Material: Rubber Quality Standard: EN14540,BS6391   Hose & Coupling Sizes   Size Large Diameter High water flow Hydrant Ready Easy Handing Pump Ready 1’’ √ √ √ √ √ 1.5’’ √ √ √ √ √ 2’’ √ √ √ √ √ 2.5’’ √ √ √ √ √ 3’’ √ √ √ √ √ 4’’ √ √ √ √ √   Features:   Working Pres...
  • Chinese Professional Fire Hose 100mm - White color Water Hose fire hose PVC rubber fire hose  – Minshan

    Chinese Professional Fire Hose 100mm - White color Water Hose fire hose PVC rubber fire hose – Minshan

    Specifications Tube and cover: PVC Reinforcement: 100% virgin high tenacity polyester Jacket    Technical Characteristics: _ excellent abrasion-resistance _ heat resistant _ seawater and weather resistant _ resistant to oil and petrol _ resistant to alkalies, acids, liquids, chemicals _ ageing, ozone and UV rays resistant _ excellent adhesion between rubber and jacket _ temperature range from -30°C up to +80°C _ maintenance free _ cleaning and drying not necessary Features: Working Press...
  • Wholesale Fire Hydrant Parts - JOHN MORRIES Fire Hose Coupling – Minshan

    Wholesale Fire Hydrant Parts - JOHN MORRIES Fire Hose Coupling – Minshan

    Features:   –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings       DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Working P...
  • Good Quality Water Stop Valve - EPDM Fire Hose – Minshan

    Good Quality Water Stop Valve - EPDM Fire Hose – Minshan

    Specification Jacket: 100% Virgin Polyester Jacket,Single Jacket, Double Jacket, Twill or Plain Weave high performance in abrasion-resistance Lining: EPDM rubber tube Package: Rolled, packed in carton or loaded in pallet Quality Standard: EN14540,BS6391 Construction:The hose consists of an EDPM lining , and single fabric jacket formed from polyester yarn. The lining adheres to the jacket.  The hose is designed for fire protection purposes.   Hose & Coupling Sizes   Size Large Diame...
  • China Factory for 3/4inch Brass Nozzle - Pendent Fire Sprinkler – Minshan

    China Factory for 3/4inch Brass Nozzle - Pendent Fire Sprinkler – Minshan

    Working principle:   The red liquid on the fire sprinkler is an extremely sensitive thing to heat. When the temperature rises, it quickly expands, breaking the glass that holds it, and then the pressure sensor in the glass will make the fire sprinkler pump spray water.   Specification:   MODEL Nominal Diameter Thread Flow Rate K Factor Style T-ZSTX DN15 R1/2 80±4 5.6 Pendent fire sprinkler DN20 R3/4 115±6 8.0   How to use:   1. The installation distance of the spray head is general...
  • Online Exporter Industrial Spray Nozzle - STORZ Fire Hose Coupling – Minshan

    Online Exporter Industrial Spray Nozzle - STORZ Fire Hose Coupling – Minshan

    Features:   –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃   Different Type Hose Couplings         DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Wor...
  • OEM/ODM Supplier Water Mist Pump - JOHN MORRIES Fire Hose Coupling – Minshan

    OEM/ODM Supplier Water Mist Pump - JOHN MORRIES Fire Hose Coupling – Minshan

    Features:   –High strength –Highly durable –Precisely designed –Quick and easy connection –Application specific design –Corrosion resistance –Resistant to high pressure –Temperature Degree :-20℃ to 40℃ Different Type Hose Couplings       DATA SHEET Size 1 1/2’’*1 1/2’’ 2’’*2’’ 2 1/2’’*2 1/2’ Material Aluminium Brass Type GOST/NST/STORZJOHN MORRIES/MACHINO/FRENCH/SPAINISH Strength Test Pressure 2.4MPA Working P...